Switch Settings
SWITCH NAME
SENS
(Rotary SW)
F
4
NOTE 1
MB (Toggle SW)
ON
NOTE 2
SW
(Piano Key SW)
OFF
8
7
6
5
4
3
2
1
ON
NOTE 1:
Set the groove on the switch to the desired position.
NOTE 2:
When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the
circuit card.
SWITCH
SETTING
NUMBER
POSITION
4-F
Set the switch to match the AP Number (04-31) to be
set by CM05
SW-8: ON
AP No.
SW-8: OFF
SW No.
0-3
Not used
UP
DOWN
ON
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
5
OFF
6
OFF
7
OFF
ON
8
OFF
FUNCTION
04 05 06 07
08 09 10
20 21 22 23
24 25 26 27
4
5
6
7
8
9
For make-busy
For normal operation
For make-busy No. 0 circuit
For normal operation
For make-busy No. 1 circuit
For normal operation
For make-busy No. 2 circuit
For normal operation
For make-busy No. 3 circuit
For normal operation
Not used
AP No. 04-15
AP No. 20-31
– 464 –
PN-4RSTB (MFR)
11
12 13 14 15
28 29 30 31
A
B
C
D
E
F