NEC NEAX 2000 IPS Installation Manual page 193

Internet protocol server installation procedure manual
Hide thumbs Also See for NEAX 2000 IPS:
Table of Contents

Advertisement

• 4W E&M Trunk (PN-2ODT)
When connecting the E and M, make the installation cable by using the connector attached with the
PN-2ODT card.
NOTE:
Both No. 0 and No. 1 circuits must be set to same purpose (2-wire or 4-wire) in one PN-2ODT
card.
CN1
08
07
06
05
J
04 M1
03 E1
02 M0
01 E0
LT00
MDF Cross Connection for 4W E&M Trunk Card
PIM0
PN-2ODT
2
LEN001
(No. 1)
LEN000
(No. 0)
TxR0
TxT0
LEN000
(No. 0)
RcvR0
RcvT0
TxR1
TxT1
LEN001
(No. 1)
RcvR1
RcvT1
INSTALLATION CABLE
LTC0
J
P
1
1
26
26
2
2
27
27
3
3
28
28
4
4
29
29
1
– 177 –
Tie Line Trunk (LDT/ODT)
MDF
(M)
(E)
(Tx Ring)
(Tx Tip)
TO TIE LINE
(Rcv Ring)
(Rcv Tip)
Continued on next page
NWA-008841-001 Rev.5.0
90ch2002.fm

Hide quick links:

Advertisement

Table of Contents
loading