b. FNS CB output signals
(1) M709 CONT (FNS CB to RB)
Signal to activate or deactivate M709
[L]: M709 ON
[H]: M709 OFF
(2) M709 F/R (FNS CB to RB)
Signal to control the rotation direction of M709
[L]: CW
[H]: CCW
(3) M710 CONT (FNS CB to RB)
Signal to activate or deactivate M710
[L]: M710 ON
[H]: M710 OFF
(4) M714 CONT (FNS CB to RB)
Signal to activate or deactivate M714
[L]: M714 ON
[H]: M714 OFF
(5) M714 F/R (FNS CB to RB)
Signal to control the rotation direction of M714
[L]: CW
[H]: CCW
(6) M715 CONT (FNS CB to RB)
Signal to activate or deactivate M715
[L]: M715 ON
[H]: M715 OFF
c.
RB output signals
(1) M709 DRV 1 (RB to M709)
Pulse signal to drive/control the Phase A of M709
(2) M709 DRV 2 (RB to M709)
Pulse signal to drive/control the Phase B of M709
(3) M710 F (RB to M710)
Pulse signal to start or stop the normal rotation of
M710
(4) M710 R (RB to M710)
Pulse signal to start or stop the reverse rotation
of M710
(5) M714 DRV 1 (RB to M714)
Pulse signal to drive/control the Phase A of M714
(6) M714 DRV 2 (RB to M714)
Pulse signal to drive/control the Phase B of M714
(7) M715 F (RB to M715)
Pulse signal to start or stop the normal rotation of
M715
(8) M715 R (RB to M710)
Pulse signal to start or stop the reverse rotation
of M715