Konica Minolta FS-110 Service Manual page 61

Finishing devices
Table of Contents

Advertisement

b. Single staple (rear, oblique)
The FNS operation signal from the main body
activates M711 (stapler movement) to extend the
distances between the two staples as well as the
two clinchers. After a predefined time period has
elapsed, M706 (stapler rotation) and M704
(clincher rotation) start to rotate the stapler/R
and the clincher/R respectively. When the sta-
plers and clinchers are set in place, M704, M706,
and M711 stop.
PS706 (main tray paper exit) turns ON by detect-
ing the last paper, and after a predefined time
has elapsed, M704 and M706 start to rotate the
stapler/R and the clincher/R back to their home
positions. The rotating actions of the stapler/R
and the clincher/R stop when PS713 (stapler
rotation HP) and PS714 (clincher rotation HP)
detect them respectively. At the same time, M711
starts moving the staplers to the home position.
The operation of M711 stops when PS711 (sta-
pler movement HP) turns ON.
c.
Two staples
When two staples are used, the staplers and the
clinchers stay in their home positions for the sta-
pling operation.
2. Signals
a.
FNS CB input signals
(1) PS711 IN (PS711 to RB to FNS CB)
Signal indicating whether the staplers (/F and /R)
are in the home position
[L]: Not in the home position
[H]: In the home position
(2) PS713 IN (PS713 to RB to FNS CB)
Signal indicating whether the stapler/R is in the
home position
[L]: Not in the home position
[H]: In the home position
(3) PS714 IN (PS714 to RB to FNS CB)
Signal indicating whether the clincher/R is in the
home position
[L]: Not in the home position
[H]: In the home position
b. FNS CB output signals
(1) M704 DRV A, A (FNSCB to RB to M704)
Pulse signal to drive/control the Phase A of M704
(2) M704 DRV B, B (FNSCB to RB to M704)
Pulse signal to drive/control the Phase B of M704
(3) M706 DRV A, A (FNSCB to RB to M706)
Pulse signal to drive/control the Phase A of M706
(4) M706 DRV B, B (FNSCB to RB to M706)
Pulse signal to drive/control the Phase B of M706
(5) M711 DRV A, A (FNSCB to RB to M711)
Pulse signal to drive/control the Phase A of M711
(6) M711 DRV B, B (FNSCB to RB to M711)
Pulse signal to drive/control the Phase B of M711
2-31
FS-110/FS-210

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-210

Table of Contents