2. Signals
a.
FNS CB input signals
(1) PS702 IN (PS702 to FNS CB)
Signal relating to the main tray upper limit posi-
tion
[L]: Non-upper limit position
[H]: Upper limit position
(2) PS703 IN (PS703 to FNS CB)
Signal relating to the main tray lower limit posi-
tion
[L]: Non-lower limit position
[H]: Lower limit position
(3) PS707 IN (PS707 to FNS CB)
Signal relating to the main tray upper limit posi-
tion in the staple mode
[L]: Upper limit position
[H]: Non-upper limit position
(4) PS715 IN (PS715 to FNS CB)
Signal relating to the counter reset
[L]: Non-counter reset position
[H]: Counter reset position
(5) M703LD (M703 to FNSCB)
2
Rotation speed detection speed of M703 (New
type only)
b. FNS CB output signals
(1) M703 DRV_F (FNS CB to M703)
Signal to drive/control the normal rotation of
M703 (Old type)
(2) M703 DRV_R (FNS CB to M703)
Signal to drive/control the reverse rotation of
M703 (Old type)
(3) M703 CONT (FNSCB to M703)
2
Rotation/stop control signal (New type only)
[L]: M703 ON
[H]: M703 OFF
(4) M703 CLK (FNSCB to M703)
2
Rotation speed control clock signal of M703
(New type only)
(5) M703 F/R (FNSCB to M703)
2
Rotation direction control signal (New type only)
[L]: M703 Counterclockwise
[H]: M703 Clockwise