CONVEYANCE SECTION

[1] Replacing the Paper Exit Roller
(Sponge Roller)
Caution:
After you have lowered the main tray, be
sure to unplug the power cord of the main
body from the power outlet.
CAUTION: When replacing the sponge rollers,
all of the 5 pairs (10 components)
must be replaced.
a.
Procedure
(1) Push up the actuator of the main tray exit with
your finger to lower the main tray.
Actuator
Paper exit roller
(sponge roller)
(2) Turn the main body's main power switch (SW1)
OFF, and unplug the power cord from the power
outlet.
Paper exit roller
Main tray
3-6
(3) Insert the end of the blade screwdriver into the
slot in the sponge roller, and twist the screwdriver
to pry apart.
Paper exit roller (Sponge roller)
(4) Place the two components of a new sponge roller
around the roller shaft so that the tabs of the
components are aligned with the dents on the
shaft. Press the components together firmly until
you hear the "click" sound.
Align
(5) To reattach the sponge roller shaft, perform the
same procedure in reverse order.
Align