[3] Removing and Reinstalling the Sta-
pler
Caution:
Make sure that the power cord of the main
body is unplugged from the power outlet.
Caution:
Do not use hands to move stapler units to
horizontal direction.
(Otherwise the belt and the gear teeth skip-
ping may occur.)
Caution:
Be sure to perform the adjustment work
described in the "FNS Stapler Upper/
Lower Positions Adjustment" of the man-
ual, "Adjustment," after you have attached
the stapler.
a.
Procedure
(1) Open the front door.
(2) Draw the stacker unit out.
(3) Remove the cartridge from the stapler.
(4) Remove four mounting screws securing the sta-
pler and the screw holding the ground cable.
Detach the stapler/F and the connector (CN181).
Stapler/F
Ground
Screw securing the ground cable
MODEL
7155/7165/7255/7272
SERVICE MANUAL
Screw
Connector
(CN181)
MANUAL
REVISED EDITION
3-19
(5) Remove two screws holding the sensor cover of
2
the stapler/R. Remove one screw securing the
wire binding band and the screw securing the
ground cable. Detach the connector (CN182) of
the stapler rotation HP PS (PS713).
Screw
Wire binding band
Sensor cover
Screw
Screw securing the
ground terminal
(6) Remove four screws. Detach the stapler/R and
the connector (CN180).
CAUTION: Take care not to damage the stapler
rotation HP PS (PS713) when
removing the stapler/R.
Stapler/R
Screw
Stapler rotation HP
PS (PS713)
(7) Reinstall the above parts following the removal
steps in reverse.
CAUTION: When installing the sensor cover of the
stapler/R, take care that the bundled cable
does not disturb the stapler rotation HPPS
(PS713) and is not nip by the gears.
DATE
Dec. 2003
2
FS-110/FS-210
Stapler/R
Connector
(CN182)
Ground
Stapler rotation
HP PS (PS713)
fs2103007
Connector (CN180)
PAGE
METHOD
3-17
REPLACEMENT

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-210

Table of Contents