[5] SD706 (three-folding gate) Control

SD706 (three-folding gate) operates the three-
folding gate, which provides the appropriate
paper passage for either one of the three oper-
ations: folding, stitch-and-fold, or three-folding.
The FNS CB (FNS control board) controls the
operation of SD706.
The related signal is PS725 (folding exit).
1. Operation
When the booklet stopper stops at the three-fold-
ing position, SD706 (three-folding gate) is acti-
vated. This operates the three-folding gate,
providing the paper passage that leads to the
three-folding stopper.
When PS725 (folding exit) has detected the trail-
ing edge of the paper and a predefined time
period has elapsed since then, SD706 is deacti-
vated.
2. Signals
a.
FNS CB output signals
(1) SD706 CONT (FNS CB to RB to SD706)
Signal to activate/deactivate SD706
[L]: SD706 ON
[H]: SD706 OFF
SD706 CONT
PS725 IN
MAIN BODY
FNS CB
SD706 CONT
24V
5V
PS725 IN
GND
RB
2-39
FS-110/FS-210
SD706
PS725