Image Stabilization Control; Overview - Konica Minolta bizhub 200 Service Manual

Hide thumbs Also See for bizhub 200:
Table of Contents

Advertisement

Theory of Operation Ver. 2.5 Jul. 2006

21. Image stabilization control

21.1 Overview

• The image stabilization control is provided to ensure that the image quality is consistent,
as caused by fluctuating environmental conditions and degraded durability.
• The Temperature Thermistor and Temperature/Humidity Thermistor are installed in the
copier to detect the temperature around the Photo Conductor and absolute humidity.
• An optimum grid voltage and optimum developing bias are applied through calculations
based on the value detected by the Temperature/humidity Sensor and the period of time
through which the Photo Conductor has been rotated.
• The Vpp (Voltage Peak to Peak) value is also varied to prevent image density from
becoming low under conditions of high temperature and high humidity when the number
of copies made increases.
• Vg/Vdc can also be changed using the Tech. Rep. Mode.
Grid Voltage (Vg)
Developing Bias
(Vdc, Vpp)
21. Image stabilization control
Temperature Thermistor
Temperature/Humidity
Thermistor
PC Counter
CPU
4040T2E604AA
71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 350Bizhub 250Bizhub 362Bizhub 282Bizhub 222

Table of Contents