7. Scanner section (IR section)
7.3.2
Original Size Detection control
• The size of the original is determined through the combination of width and length detect-
ing sensors turning ON or OFF.
• When the optional sensors are mounted, "Original Size Detecting Option" of "System
Input" available from the Tech. Rep. mode should be set to "Yes."
• The machine detects the original size when the Size Reset Switch is actuated with the
Original Cover at an angle of 15
The original size is validated when the Start key is pressed with the Original Cover at 15
or more.
• The original size is reset when the Size Reset Switch is deactuated.
for U.S and Canada area
PC208
PC202
PC203 (Option)
PC204
PC205 (Option)
PC206 (Option)
PC207 (Option)
PC208
PC209
SW201
14
or less (sensor activated).
°
PC209
CN4
BCRS
CN6
CN5
PC204
PC207
PC202
PC203
Name
Original Size Sensor 2
Original Size Sensor3
Original Size Sensor4
Original Size Sensor
Original Size Sensor6
Original Size Sensor7
Scanner Home Sensor
Original Cover Angle Sensor
Size Reset Switch
Theory of Operation Ver. 2.5 Jul. 2006
: Option
: Not to be mounted
PC205
PC206
SW201
Connect to
BCRS Board CN5
BCRS Board CN6
BCRS Board CN4
BCRS Board CN6
BCRS Board CN6
BCRS Board CN5
BCRS Board CN4
BCRS Board CN4
BCRS Board CN5
°
4040T2I597AA