Theory of Operation Ver. 2.5 Jul. 2006
(2) Toner replenishing control
• The Sub Hopper Solenoid is energized and kept so for the period of the toner replenish-
ing time (amount) established through the toner replenishing amount control.
The Sub Hopper is thus energized to replenish the supply of toner to the Developing
Unit.
• As toner level in the Sub Hopper becomes low, the Sub Hopper Solenoid is energized so
that toner may be supplied to the Sub Hopper.
• The corrected T/C is compared with the target T/C to determine if T/C is more or less
than a predetermined value. If either is detected, a faulty ATDC (TCR) Sensor results
and a Tech. Rep. call display is given.
Corrected T/C ≤ Target T/C -2.5 %
Target T/C -2.5 % ≤ Corrected T/C < Target T/C -1.5 %
Target T/C -1.5 % ≤ Corrected T/C < Target T/C -0.75 %
Target T/C -0.75 % ≤ Corrected T/C < Target T/C -0.25 %
Target T/C -0.25 % ≤ Corrected T/C < Target T/C
Target T/C ≤ Corrected T/C < Target T/C +2.5 %
Target T/C +2.5 % ≤ Corrected T/C
C. T/C recovery mode
• A T/C recovery sequence is performed if the T/C ratio detected through toner density
detection is extremely low.
• When the machine is set into the T/C recovery mode, the IU Motor is energized to per-
form the toner replenishing sequence until the correct T/C is recovered.
(1) Operation timing
• A predetermined T/C ratio is detected in toner replenishing control.
• A T/C ratio more or less than the predetermined value is detected with neither a toner
near-empty nor toner empty display given.
• The T/C recovery conditions corresponding to each operating mode are met.
<Determination of T/C recovery in different operating modes>
Toner
condition
Corrected T/C ≤ Target T/C
Toner empty
Target T/C ≥ Corrected T/C
condition
(Target T/C -2.5) ≥ (Corrected T/C) ≤
(Target T/C -1.5 %)
Toner
(Target T/C -1.5) ≥ (Corrected T/C) ≤
near-empty
condition
(Target T/C -1.0 %)
(Target T/C -1.0 %) ≤ (Corrected T/C)
(Target T/C -2.5) ≥ (Corrected T/C) ≤
Normal
(Target T/C -1.5 %)
condition
(Target T/C -1.5 %) ≤ (Corrected T/C)
: T/C recovery sequence is performed
-: T/C recovery sequence is not performed
T/C Value
T/C
13. Toner Supply section
Replenishing Time/Cycle
Faulty ATDC (TCR) Sensor
To T/C recovery mode
Full replenishing
1/2 replenishing
1/4 replenishing
Not replenished
Faulty ATDC (TCR) Sensor
Front Door
Power
Right Door
open/close
ON
open/close
-
-
-
-
-
-
-
During
copy cycle
-
-
-
-
-
-
-
-
-
-
39