Theory of Operation Ver. 2.5 Jul. 2006
11. Charge Corona section
11.1 Operation
11.1.1
Charge Corona ON/OFF control
• The Comb Electrode deposits a charge evenly across the surface of the Photo Conduc-
tor through a grid mesh.
• The corona unit has a comb electrode that discharges only toward the grid mesh. This
results in the amount of ozone produced being smaller than with the wire electrode.
• The grid voltage (Vg) applied to the Grid Mesh is controlled through the image stabiliza-
tion control.
Photo Conductor Charge Corona UNit
IU Motor (M2)
Charge Bias
Developing Bias
Transfer output
IU Motor ON
11. Charge Corona section
Comb Electrode
4040T2C524AA
4040T2E504AA