Cutout/Dimensions - MP6000 Long
Min 0.75 in. - Max 1.65 in.
Min 19.1 mm - Max 42.0 mm
Typical Checkstand
Leveling Screw Locations
MP6000 - Long Unit Counter Cutout
Figure 3-37
0.38 in. +/- 0.03 in.
9.5 mm +/- 0.8 mm
MP6000 - Long Unit Side View Dimensions
Figure 3-38
NOTE The countertop, after routing, must have sufficient strength to support the scanner and the loads placed
on top of it. If the countertop is not strong enough, add strengthening supports underneath the countertop
as required
SITE PREPARATION AND INSTALLATION 3 - 29
20.13 in. +/- 0.06 in.
511.2 mm +/- 1.5 mm
Max 18.63 in.
473.1 mm
20.13 in. +/- 0.06 in.
511.2 mm +/- 1.5 mm
(Counter Opening)
Max 18.63 in.
473.1 mm
Min 0.75 in. - Max 1.22 in.
Min 19.1 mm - Max 31.0 mm
(Cashier Side)
11.63 in. +/- 0.06 in.
295.3 mm +/- 1.5 mm
0.38 in. +/- 0.03 in.
9.5 mm +/- 0.8 mm
(Counter to Top of Unit)
5.1 in.
128.5 mm
4.00 in.
101.6 mm