 AH20MC-5A
Item
Number of axes
Storage
Unit
Connection with a CPU
module
Motor control
Maximum speed
Operating
switch
Input signal
Detector
Servo
Output signal
output
signal
External communication
port
Expansion storage
device
Number of basic
instructions
Number of applied
instructions
M-code
G-code
3 - 5 6
12 axes
The capacity of the built-in storage is 64 ksteps.
Motor unit
Users can set the initial register involved in the data exchange in a
CPU module, and the number of registers involved in the data
exchange in the CPU module. Four hundred data registers at most
can be involved in the data exchange.
Delta high-speed motion control system DMCNET (Delta Motion
Control Network)
The response time is one millisecond.
Single axis: 500 kpps
Two-axis interpolation: 500 kpps
STOP/RUN (automatic/manual switch)
X0.10+, X0.10-, X0.11+, X0.11-, X0.12+, X0.12-, X0.13+, X0.13-,
X0.14+, X0.14-, X0.15+, X0.15, X0.0+, X0.0-, X0.1+, X0.1-, X0.2+,
X0.2-, X0.3+, X0.3-, X0.8+, X0.8-, X0.9+, and X0.9-
Y0.8+, Y0.8-, Y0.9+, Y0.9-, Y0.10+, Y0.10-, Y0.11+ and Y0.11-
Mini USB port
Ethernet port
DMCNET port
Mini SD card
The maximum capacity is 32 GB.
27
130
 OX0~99 (motion subroutine/positioning program): M02 (The
execution of the program stops. (END))
 M00~M01, M03~M101, and M103~M65535:
The execution of the program pauses. (WAIT)
Users can use them freely.
G0 (rapid positioning), G1 (linear interpolation), G2 (circular
interpolation, clockwise), G3 (circular interpolation,
counterclockwise), G4 (dwell), G17 (XY plane selection), G1 8 (ZX
plane selection), G19 (YZ plane selection), G90 (absolute
programming), and G91 (incremental programming)
Ch ap te r 3 Pro duc t Spec ifica tions
Specifications
AH20MC-5A
Compound unit
Mechanical unit