AH5 00 Hardw are Manu al
Error
Description
code
Illegal gateway mask
16#6003
(SM1107)
The IP address filter is set
16#6004
incorrectly. (SM1108)
The static ARP table is set
16#6006
incorrectly. (SM1108)
Illegal network number
16#6008
(SM1107)
16#6009
Illegal node number (SM1107)
The trigger in the email is set
16#6101
incorrectly. (SM1112)
The interval of sending the
16#6102
email is set incorrectly.
(SM1112)
The device containing the
data specified as the
16#6103
attachment exceeds the
device range. (SM1112)
The SMTP server address is
16#6106
incorrect. (SM1112)
SMTP authentication error
16#6108
(SM1112)
The SMTP server needs to be
16#6110
authenticated. (SM1112)
The specified email address
16#6111
does not exist. (SM1112)
The remote IP address set in
16#6200
the TCP socket function is
illegal. (SM1196)
The remote IP address set in
16#6209
the UDP socket function is
illegal. (SM1196)
Only auxiliary relays, data
16#6300
registers, and link registers
can be used in the Ether Link.
The device used in the Ether
16#6301
Link exceeds the device
range.
The length of the data
16#6302
exchanged in the Ether Link
exceeds the limit.
The node used in the
16#6305
communication command is
different from the local node.
9 - 8
Remedy
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG again.
Set the Ethernet parameter for the CPU module in
HWCONFIG again.
Set the Ethernet parameter for the CPU module in
HWCONFIG again.
Check the network configuration in NWCONFIG,
and download it again.
Check the network configuration in NWCONFIG,
and download it again.
Set the Ethernet parameter for the CPU module in
HWCONFIG again.
Set the Ethernet parameter for the CPU module in
HWCONFIG again.
Set the Ethernet parameter for the CPU module in
HWCONFIG again.
Make sure that the address is correct, and set the
Ethernet parameter for the CPU module in
HWCONFIG again.
Check the user name, and the password. Set the
Ethernet parameter for the CPU module in
HWCONFIG again.
Check the user name, and the password. Set the
Ethernet parameter for the CPU module in
HWCONFIG again.
1. Check whether the email address is correct.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG again.
Check the setting of the Ether Link in NWCONFIG,
and download it again.
Check whether the device used in the Ether Link is
within the device range supported by the CPU
module.
Check whether the length of the data exchanged in
the Ether Link is within the range supported by the
CPU module.
Check the setting of the Ether Link in NWCONFIG,
and download it again.