Wire Circuit Legend; Service Manual - Genie ZX-135/70 Service Manual

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

Service Manual

Wire Circuit Legend

Circuit numbering
1
Circuit numbers consist of three parts: the
circuit prefix, circuit number and circuit suffix.
The circuit prefix indicates the type of circuit.
The circuit number describes the function of
the circuit. The circuit suffix provides an
abbreviation for the number or may be used to
further define the function of this portion of the
circuit. It also may be used to indicate the final
end of the circuit, i.e., LS or limit sw.
2
The circuit number may be used more than
once in a circuit.
For Example:
C 74 PL – This is the circuit for the lockout valve
#1. C stands for control, 74 is the number of the
circuit for the primary #1 lock out valve. PL stands
for Primary Lockout.
S 62 BST – This is the circuit that communicates to
the onboard computers of the machine that the
boom is fully stowed. S stands for safety, 62 is the
number of the circuit for boom stowed and BST
stands for Boom Stowed.
P 48 LP – P stands for power. 48 is the circuit
number for work lamps and LP stands for Lamp.
R 48 LP – R stands for relay. In this case it is the
wire that feeds the relay coil for the work lamp. All
other numbers remain the same.
V61AXR – V stands for valve power. Number
61 stands for axle retracted circuit; AXR stands for
Axle retracted.
R46HN – R stands for Relay output, supplying
power to the horn (HN). Number 46 is the circuit
number for the horn.
222
Circuit prefix
C
D
E
G
N
P
R
S
V
ZX-135/70
August 2014
Control
Data
Engine
Gauges
Neutral
Power
Relay Output
Safety
Valve
Part No. 218700

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents