Genie ZX-135/70 Service Manual page 98

Hide thumbs Also See for ZX-135/70:
Table of Contents

Advertisement

August 2014
Screen or
Menu
Machine Status With key switch on, press the
(enter)(plus)(minus) buttons at the
same time.
With key switch
Unit of
the enter button and turn key switch to
Measure and
on position.
Language
Release the enter button and press
(plus)(minus)(minus)(plus).
Default Reset
With key switch
the enter button and turn key switch to
on position.
Release the enter button and press
(minus)(minus)(previous)(previous).
Part No. 218700
Procedure
, press and hold
OFF
, press and hold
OFF
ZX-135/70
Description
Hydraulic pressure PSI
(English)
Hydraulic pressure kPa
(metric)
Primary boom to secondary
boom angle
Primary boom length
Secondary boom angle*
Secondary boom length
Jib bellcrank angle
*(referenced to chassis tilt
angle)
Metric/English (measurement
units)
Set engine
Delete drive functions
Delete boom function speeds
Delete lift function ramps
Delete all (Contact Genie
Product Support before using
this option)
Service Manual
Display Module
Range or Selection
0-4500 PSI
0-31000 kPa
+22° to +136°
=0', >0', >22
-3.5° to 75°
=0FT, >0 FT
-10° to +10°
English, German,
French, Spanish,
Portuguese, Italian,
Dutch, and Swedish.
Deutz TD2011L04i
(DL04i)
Perkins 1104D-44T
(P1104)
83