27 Press and hold the engine start button for
approximately 5 seconds to shut off the
engine and to save the calibration settings.
Note: Do not turn the engine off with the key switch
or red Emergency Stop button or all calibration
points or values will not be saved.
28 Press the enter or previous button on the
LCD screen until EXIT is displayed.Press the
plus button to select YES, then press the
enter button to accept.
29 Turn the key back to the run position and
remove the key from the service/bypass key
switch. Insert the key into the main key switch
and turn it to ground controls.
30 Wait approximately 20 seconds and turn the
machine off by pressing the red Emergency
Stop button in.
31 Remove the fastener that was temporarily
installed. Close the control box door and
install the door retaining fasteners.
Note: When the control box door is closed, the
calibration toggle switch is automatically activated
to exit out of calibration mode.
32 Use the key to turn the service/bypass key
switch to the run position.
Note: Be sure that the service/bypass key switch is
in the run position before attempting to operate the
machine.
33 Pull out the red Emergency Stop button. Start
the engine and lower the boom to the stowed
position. Be sure there are no calibration
faults shown on the display.
Part No. 218700
Jib Boom Components
ZX-135/70
Service Manual