Service Manual
Fault Codes
Error Source
Platform Overload
Footswitch Timeout
Engine Speed
Oil Pressure
Water/Oil Temperature
Oil Pressure Sender
Water/Oil Temp Sender
Axle Extend/Retract Buttons Fault Check (both
Axle Valve
DCON CAN Bus
CAN Bus
206
Error Type
Fault Check
Display message on LCD. Disable all
(if active)
functions from PCON. Limit functions
at TCON to AUX Power. FUEL
POWER P9B FAULT
Calibration check
Display message on LCD
Range Check
Display message on LCD
(underspeed)
Range Check (low
Display message on LCD
oil pressure)
Range Check
Display message on LCD
(high temp)
Fault Check
Display message on LCD
Axle extend/retract disabled. Display
buttons pressed)
message on LCD
Fault Check
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
Fault Check
Display message on LCD Disable
propel
Fault Check
Display message on LCD
Effects
ZX-135/70
August 2014
Recovery Actions
Check for an overload in the platform.
Check the overload switch mounted on
the platform support.
Recycle power
Engine is running below 50 RPM.
Check fuel system.
Oil pressure is low. Check sender and
oil level.
Engine is overheating. Check sender,
water or oil level or radiator/heat
exchanger.
Check wiring to senders for opens or
shorts. Repair or replace senders.
Check ribbon and connector from
membrane switch. If necessary
replace membrane switch.
Check for defective or damaged
wiring. Check for an open or shorted
valve coil. Repair or replace as
necessary.
Check CAN bus wiring from TCON to
DCON through rotator. Repair or
replace wiring or DCON.
Check CAN bus wiring from TCON to
SCON/PCON. Repair or replace wiring
or SCON/PCON.
Part No. 218700