August 2014
9
Press and hold the enter button on the
ground control panel while pulling out the
ground controls red Emergency Stop button to
the on position. Hold the enter button for
approximately 5 seconds and then release it.
1 Run
2 Service / Bypass
3 Recovery
10 Enter sensor calibration mode by pressing the
buttons at the ground controls in the following
sequence: (plus)(enter)(enter)(plus).
Part No. 218700
Delete all Steer Sensor Calibrations
11 Press the enter or previous button on the
LCD screen until DELETE ALL STEER
SENSORS CALIBRATION is displayed.Press
the plus button to select YES, then press the
enter button to accept.
12 Press the enter or previous button on the
LCD screen until EXIT is displayed.
13 Press the plus button to select YES, then
press the enter button to accept.
14 Proceed to step 21.
Delete a Single Steer Sensor Calibration
15 To calibrate a single steer sensor, delete the
specific steer sensor calibration
16 Press the enter or previous button on the
LCD screen until DELETE _____ STEER
SENSORS CALIBRATION is displayed.
Example: DELETE BLUE END BLUE SIDE
STEER SENSORS CALIBRATION (FL).
17 Press the plus button to select YES, then
press the enter button to accept.
18 Press the enter or previous button on the
LCD screen until EXIT is displayed.
19 Press the plus button to select YES, then
press the enter button to accept.
ZX-135/70
Service Manual
Axle Components
195