Turntable Rotation Components
13 Place the digital level along the Y axis of the
turntable.
1 + Y Axis
2 - Y Axis
14 Press the plus button or minus button to
adjust the display to the exact value shown on
the digital level and press the enter button.
Note: If the measured angle already matches the
angle shown on the display at the ground controls,
press the plus button or minus button to change
the angle and then change back to the measured
value. The system must detect a change in
displayed value to record the calibrated value.
15 Press the enter or previous button on the
LCD screen until EXIT is displayed.
16 Press the plus button to select YES, then
press the enter button to accept.
17 Wait approximately 20 seconds and turn the
machine off by pressing the red Emergency
Stop button in.
190
18 Remove the fastener that was temporarily
installed. Close the control box door and
install the door retaining fasteners.
Note: When the control box door is closed, the
calibration toggle switch is automatically activated
to exit out of calibration mode.
19 Use the key to turn the service/bypass key
switch to the run position.
Note: Be sure that the service/bypass key switch is
in the run position before attempting to operate the
machine.
20 Start the engine. Be sure there are no
calibration faults shown on the display.