Two-axis position control unit (nc221 mode)
Table of Contents

Advertisement

Setting Parameters
In-Position Zone (X axis:
405, Y axis: 805)
34
This parameter is used for reading the error counter value in the status area.
Decide to read or not to read the error counter value when setting the gain
set value.
If the parameter is set to error counter value read, the error counter value will
be output to words 17 to 20 (the data read area) of the status area in 8-digit
BCD. Words 17 to 18 will be used for single axis error counter value read.
Reading X- and Y-axis Error Counter Values:
Word
15
14
13
12
11
17
X-axis sign
3
18
X-axis 10
19
Y-axis sign
3
20
Y-axis 10
21
The plus or minus sign will be displayed with 1 or 0 in bit 12.
The top word of the data read area varies with the axis when reading the
error counter value.
The top word of the data read area when reading the X- and Y-axis error
counter values: 21
The top word of the data read area when reading the X- or Y-axis error
counter value: 19
The top word of the data read area when not reading the X- or Y-axis error
counter value: 17
Checks the error counter count of the servo system. When the count in the
error counter reaches the value set here, the corresponding In Position flag
turns ON and relays this condition externally. The flag remains ON as long as
the count remains below the in-position zone. This flag will not turn ON while
pulses are being input into the error counter regardless of the value of the
counter.
1 Word
1 Word
In-position
Address
1
0
zone
Bit
10
9
8
7
6
5
4
6
5
X-axis 10
X-axis 10
2
1
X-axis 10
X-axis 10
6
5
Y-axis 10
Y-axis 10
2
1
Y-axis 10
Y-axis 10
Top word of data read area
15 14 13
12
0
0
0
0
1: Minus
2: Plus
Range: 1 to 999 pulses
(Default: 10)
Section 3-3
3
2
1
0
4
X-axis 10
X axis
0
X-axis 10
4
Y-axis 10
Y axis
0
Y-axis 10