Precautions When Using C500-NC222-E in NC221 Mode
Address
Y-axis
800
parameter
801
data
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
Type
NC221
Unit setting
0
Pulse rate
1
Rotating
0
direction
Encoder
01
type
Gain
200
In-position
10
zone
Backlash
0
compensa-
tion
Stroke limit
999999
(+)
Stroke limit
999999
(–)
Zone setting
01000100
Home shift
0
Maximum
10000
speed
Jog forward
2000
maximum
speed
Origin
0
search direc-
tion
Origin com-
0
pensation
Origin
5000
search maxi-
mum speed
Origin
5
search
acceleration
and decel-
eration
Origin
1000
search low
speed
Deceleration
500
stop pulse
number
Wiring check
---
function
Emergency
0
stop counter
capacity
External out-
00032768
put control
setting
Initial data and data attributes
NC221 mode
0
1
0
01
200
10
0
999999
999999
01000100
0
FFFFFFFF (*1: see
note)
FFFFFFFF (*2: see
note)
0
0
5000
5
1000
500
---
7024
00032768
Section 1-7
NC222
0
1
0
001
200
10
0
999999
999999
01000100
0
40010000
10002000
0
0
5000
5
1000
00000500
01100011
---
00032768