Replacing A System Fan; Replacing The System Fans (Sr1530Cl); Figure 87. Disconnecting System Fan Cables (Sr1530Cl) - Intel SR1530CL User Manual

Server system
Table of Contents

Advertisement

Replacing a System Fan

Caution: The system fans are NOT hot swappable. Before removing or replacing a system fan, you
must first take the server out of service, turn off all peripheral devices connected to the
system, turn off the system by pressing the power button, and unplug the AC power cord
from the system or wall outlet.
Note: The fans that are integrated into the power supply cannot be replaced separately. If one of
the fans in the power supply fails, the power supply must be replaced.
The system fans at the front of the server system can be individually replaced if one of
them fails. If a fan in the power supply fails, the power supply must be replaced. Use the
following steps to replace a system fan or the PCI cooling fan.

Replacing the System Fans (SR1530CL)

1. Observe the safety and ESD precautions at the beginning of this book. See
Information" on page
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see
System
4. Remove the processor air duct. For instructions, see
Duct" on page 31
5. Disconnect the two system fan cables from the server board. See letters "A" and
"B" in the following figure.
86
iii.
Cover".

Figure 87. Disconnecting System Fan Cables (SR1530CL)

Intel
A
B
®
Server System SR1530CL / SR1530HCL / SR1530HCLS
"Removing the Server
"Removing the Processor Air
AF001180
"Safety