X6#
= Verbose mode
X6^
= Baud rate
X6&
= Parity
X6*
= Data bits
X6(
= Stop bits
X7)
= Port type
X7#
= Web page priority flag
X7$
= Password
NOTES:
The following characters are invalid or not recommended in the name:
= ' [ ] { } < > ` " ; : | \ ?
User password cannot be assigned if no admin password exists (returns error
code
). When admin password is cleared, then user and all security level
E14
passwords are deleted.
X7%
= Daylight Savings Time
X7^
= Event number
X7&
= Event data size
NOTE:
The parameter is case sensitive and may be optionally preceded by
O
(Or) to logically combine with content instead of replacing it.
X7(
= Number of bytes to read
X8)
= E-mail event number or mailbox
X8!
= E-mail recipient address
X8@
= E-mail account
SMX System MultiMatrix Switcher • SIS Configuration and Control
0
= clear/none
(default for Telnet connections)
= verbose mode (default for RS-232
1
and RS-422 connections)
= tagged responses for queries
2
= verbose mode and tagged for
3
queries
9600 (default), 9200, 38400, 115200
O = odd
E = even
N = none
M = mark
S = space
7, 8
1, 2
0 = RS-232 (default)
1 = RS-422
2 = RS-485
0 = internal (default factory reset)
1 = user
12 digits, alphanumeric
User or admin
and
space
0
= Daylight Savings Time off or ignore
= Daylight Savings Time on
1
(USA - April to October)
2
= Daylight Savings Time on
(Europe - March to October)
= Daylight Savings Time on
3
(Brazil - October to March)
0
-
99
Event must be running.
= bit
b
= byte (8 bits)
B
S
= short (16 bits)
= long (32 bits)
L
-
1
127
-
1
64
Response is 3 digits with leading zeros.
65
-
72
~ , @
(And) or
A
54