Loud Bell/Relay
Control
Programming
2.12
The
Loud Bell and Relay Control parameters, including Access Codes and Data
Codes are provided in Table 2-6. They are:
LOUD BELL OR RELAY CONTROL:
Determines whether the
dry contacts will close to activate a loud bell ringer, or to activate
optional equipment such as security doors and gates.
Preprogrammed Value = Loud Bell.
WARNING
FOR
DRY CONTACTS:
DRY CONTACT RATING
Do not connect ringer loads or AC power directly to
DC Current
DC VObO~
the dry contact. The dry contact should only be used
2.0 amp
20 Volts
in conjunction with a dry contact interface or a 24
0.8 amp
30 Volts
Vdc supply and relay.
0.6 amp
40 Volts
LOUD BELL RINGING/RINGING
OVER
PAGING
BY
LINE (DURING DAY MODE):
Determines which lines will
close the dry contacts during an incoming call when the system is in
Day Mode.
Rreprogramrned Value = Loud Bell Ringing on all lines (during Day
Mode).
LOUD BELL RINGING/RINGING
OVER
PAGING
BY
LINE (DURING NIGHT MODE):
Determines which lines will
close the dry contacts during an incoming call when the system is in
Night Mode.
Preprogrammed Value = Loud Bell Ringing on all lines (during Night
Mode).
AUTO/MANUAL
RELAY
CONTROL:
Specifies whether the
relay control will turn off automatically after a programmable length of
time (see below), or that it must be manually turned off following
operation.
Note: Auto Mode should be selected if the relay activates motorized
equipment (e.g., a motorized gate) which only neeak a signal to start it.
If the relay contact will be usedfor equipment which requires both a
start (ON) and stop (OFF) code (e.g., to open a door and close it after
the person has entered), then Manual Mode should be chosen.
Preprogrammed Value = Automatic Return to OFF.
AUTO RETURN TO OFF TIMING:
Defines the length of time
that the relay contact will remain open, before closing automatically.
Values range from 20 ms to 3 seconds. Used in conjunction with
AUTO/MANUALRELAY CONTROL.
Preprogrammed Value = 1 second.
Programming
Page
18