Detailed Zone Merge Correction Procedure; Verify Fabric Merge Problem; Edit Zone Config Members - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks fabric os procedures v3.1.x/4.1.x user guide (aa-rs23c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Troubleshooting
2. Enter the cfgDisable command.
3. Enter the cfgClear command.
4. Enter the switchdisable command.
5. Enter the switchenable command. This automatically evokes the
6. See

Detailed Zone Merge Correction Procedure

For more information regarding Zoning, refer to the HP StorageWorks Zoning
Version 3.1.x/4.1.x User Guide .
For detailed troubleshooting of zone merge issues, follow the steps below.

Verify Fabric Merge Problem

1. Enter the switchshow command at the command line to validate that the
2. See

Edit Zone Config Members

3. Log into one of the segmented Fabrics as admin.
4. Enter the cfgshow command.
5. Print the output from the cfgShow command.
6. Start another Telnet session and log into the next fabric as admin.
7. Run the cfgShow command.
8. Print the output from the cfgShow command.
208
Caution:
Be careful when using the cfgclear command because you can
inadvertently delete the Zone configuration in the fabric. Make sure you are
deleting the "incorrect" configuration.
cfgSave command.
The two fabrics will be remerged.
"Detailed Zone Merge Correction
detailed troubleshooting instructions.
segmentation is due to a zone issue.
"Zoning Setup
Issues" on page 206 to view the different types of zone
discrepancies.
Typing the "*" symbol after the command displays list of all config names.
Procedure" on page 208 for more
Fabric OS Procedures Version 3.1.x/4.1.x User Guide