Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee8;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051eef;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
N
051f00;
FC4s: FCP [EMC
Fabric Port Name: 20:0f:00:60:69:10:9b:5b
2. Look for the device in the list of the Simple Name Server (SNS). The SNS
3. Check the edge device documentation to determine if there is a timeout setting

Fabric OS Procedures Version 3.1.x/4.1.x User Guide

3;21:00:00:20:37:d9:6f:eb;20:00:00:20:37:d9:6f:eb; na
3;21:00:00:20:37:d9:77:45;20:00:00:20:37:d9:77:45; na
2,3;50:06:04:82:bc:01:9a:0c;50:06:04:82:bc:01:9a:0c; na
SYMMETRIX
lists all of the nodes connected to that switch, which allows a user to
determine if a particular node is accessible on the network.
— If the device is not present in the SNS, the search is narrowed to the
virtual SAN cable. The problem is between the storage device and the
switch. This is not a host problem and may indicate a timeout or
communication problem between the edge devices and the Name Server.
Move on to
step
— If the device is listed in the SNS, the search is narrowed; the problem is
between the storage device and the host. There may be a zoning mismatch
or a host/storage issue. See
or parameter that may be re-configured. If this does not solve the
communication problem, contact the support organization for the product that
appears to be timing out.
0005]
0005]
5267]
3.
"Check for Zoning
Troubleshooting
Discrepancies".