Kernel Software Watchdog Related Errors

This section describes the kernel software Watch Dog-related errors.

kSWD-APP_NOT_REFRESH_ERR

Message
Explanation
A critical kernel software error occurred in the Watch Dog subsystem. A kernel
application is not able to refresh. See the specified PID number to find out
which application is failing. The switch will reboot (on single-CP switches) or
fail-over (on dual-CP switches).
Action
Run the savecore command to find if a Core File was created. If a Core
File is found, select the FTP the file option.
Copy the error message and contact customer support.
Severity
Critical

kSWD-kSWD_GENERIC_ERR_CRITICAL

Message
Explanation
A critical application error was reported in the Watch Dog subsystem. Refer to
the string at the end of the error message for specific information. The switch
will reboot (on single-CP switches) or fail-over (on dual-CP switches).
Action
Run the savecore command to find out whether a Core File was created. If
a Core File is found, select the FTP the file option.
Copy the error message and contact customer support.
Severity
Critical
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
Critical kSWD-APP_NOT_REFRESH_ERR, 1, (kSWD)Application with
pid <PID number> not refreshing watchdog.
Critical kSWD-kSWD_GENERIC_ERR_CRITICAL, 1, kSWD: <error
string>