Initial Configuration
3. Check that the switch and ports are online.
4. (Optional) Verify that the device is connected to the switch by entering the
switch:admin> nsshow -r
{
Type Pid COS PortName NodeName SCR
NL 2016ce; 3;21:00:00:04:cf:75:78:d2;20:00:00:04:cf:75:78:d2; 0
FC4s: FCP [SEAGATE ST318452FC 0001]
Fabric Port Name: 20:16:00:60:69:90:03:f8
N 201700; 3;21:00:00:e0:8b:05:a3:c9;20:00:00:e0:8b:05:a3:c9; 1
Fabric Port Name: 20:17:00:60:69:90:03:f8
The Local Name Server has 2 entries }
switch:admin>
32
nsshow [-r] command.
Use the -r option to replace the TTL attribute output with SCR (state change
registration) information in the display. SCR is the state change registration of
a device. This value indicates what type of RSCN a device registers to receive.
Example: Display the local name server information.
Fabric OS Procedures Version 3.1.x/4.1.x User Guide