Connect Devices to the Switch
Power off all devices (to minimize Port Logins (PLOGIs)) and connect them to
the switch, according to your topology. For devices that cannot be powered off,
connect the devices, but use the portdisable command to disable the port on
the switch.
When powering the devices back on, wait for each device to complete the fabric
login before powering on the next one.
Verifying Device Connectivity
To verify that you have fabric-wide device connectivity, display the fabric-wide
device count. The number of devices listed in the Name Server (NS) should reflect
the number of devices that are connected.
To display the fabric-wide device count from a switch:
1. Log into the switch as the admin user.
2. (Optional) Enter the switchshow command to verify that the storage
3. (Optional) Enter the nsshow command to verify that the storage devices
4. Enter the nsallshow [type] command at the command line. This
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
devices are logged in.
have successfully registered with the Name Server.
command displays 24-bit Fibre Channel addresses of all devices in the fabric.
type
Specify the FC-PH type code. This operand is optional. The
valid values for this operand are 0 to 255. Below are two specific
FC-PH device type codes:
8 = FCP type device
4 , 5 = FC-IP type device
Other FC-PH types are displayed in the format "x ports
supporting FC4 code," where x is the number of ports of a type,
and code is the FC-PH type code.
Example:
Initial Configuration
35