7. Log into each switch in the fabric.
8. Issue the switchdisable command.
9. Issue the configure command and change the Core Switch PID Format to
10. Issue the configenable [effective_zone_configuration]
11. Issue the switchenable command. Enable the core switches first, then the
12. Rebuild the device entries for the affected fabric using the cfgmgr
Note:
13. If you are not using multi-pathing software, vary on the disk volume groups.
14. If you are not using multi-pathing software, mount all devices again and
15. If you are using multi-pathing software, re-enable the affected path.
16. Repeat for all fabrics.
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
rmdev -Rdl fcs0
1.
command. For example:
configenable my_config
edges.
command. For example:
cfgmgr –v
This command may take several minutes to complete.
The proper usage would be varyonvg <volume_group_name>. For
example:
varyonvg datavg
restart I/O. For example:
mount /mnt/jbod
Updating Switches to the Core PID Addressing
159