HP StorageWorks MSA 2/8 - SAN Switch User Manual page 177

Hp storageworks fabric os procedures v3.1.x/4.1.x user guide (aa-rs23c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

The switchshow command also displays the following information for ports
on the specified switch:
The following example shows information about the SAN Switch 2/16 using the
switchshow command.
Example
switch:admin> switchshow
switchName:
switchType:
switchState:
switchMode:
switchRole:
switchDomain:
switchId:
switchWwn:
switchBeacon:
Zoning:
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
12.1 = SAN Switch 2/32
16.2 = SAN Switch 2/8 EL
— switchstate - Displays the switch state: Online, Offline,
Testing, or Faulty.
— switchrole - Displays the switch role: Principal, Subordinate, or Disabled.
— switchdomain - Displays the switch Domain ID.
— switchid - Displays the embedded port D_ID of the switch.
— switchwwn - Displays the switch World Wide Name.
— switchbeacon - Displays the switch beaconing state: either ON or OFF.
— Module type - The GBIC type if a GBIC is present.
— Port speed - The speed of the Port (1G, 2G, N1, N2, or AN). The speed
can be fixed, negotiated, or auto negotiated.
— Port state - The port status.
— Comment - Displays information about the port. This section may be
blank or display WWN for F_port or E_port, Trunking state, upstream or
downstream status.
sw10
16.1
Online
Native
Subordinate
52
fffc34
10:00:00:60:69:c0:05:61
OFF
ON (fmng1)
Diagnostics and Status
177

Advertisement

Table of Contents
loading

Table of Contents