Step 3: Signaling Layer
Depending on your country and it's corresponding trunk property, in the
Triton E1 Trunk Configuration dialog box, configure the following
fields:
• Set Calling Party Category to - the Calling Party Category
indicates the type of calling party, (e.g. operator, pay phone,
priority, ordinary subscriber). Select 1, 2 or 3 (for ordinary
subscribers, refer to Table 1). If the suscribed line is intended for
other purposes, contact your CO for the proper value.
• Add extra digits before caller ID - consult your CO to find out if
any extra digits are needed.
• Incoming sequences - select check box and configure the sequence
according to Table 1.
• In-call signaling - configure the in-call signaling value according
to Table 1.
Note:
Consult your CO to find out if caller ID digits are provided in the
lines.