Altigen AltiContact Manager Version 4.6 Administration Manual page 212

Table of Contents

Advertisement

Setting General Trunk Attributes
Parameter
Message Waiting
Signal Type
Flash Duration (ms)
Ringing Frequency
(Hz)
Line Disconnect
Signal
Caller ID
Transmission
Methods
Receiver/
Transmission Gain
7-10 AltiContact Manager Administration Manual
Description
Type of Message Waiting indicator for the phone set:
• None
• FSK/SDMF—Frequency Shift Keying with and
Single Data Message Format.
• FSK/MDMF—Frequency Shift Keying with
Multiple Data Message Format.
Specifies the Flash Duration time in milliseconds,
with the following set ranges: 85-750, 50-600, 100-
700, 150-800, 200-900, 300-1000.
Select the frequency in Hertz that is necessary for the
equipment attached to this line, set to either 28 or 20.
The loop break desired for answering supervision.
Select the Enable Loop Current Break check box
and select the Loop Current Break Duration in
milliseconds.
Select the type of caller ID transmission method:
• CID between 1st and 2nd ring—caller ID
transmitted between first and second ring.
• DT-AS + CID prior to ringing—dual tone
alerting signal sent prior to ringing.
• RP-AS + CID prior to ringing—ring pulse
alerting signal sent prior to ringing.
Slide setting adjusts the incoming volume from
-6 dB to 6 dB for every Triton Analog Trunk
channel.
The default setting is 0 dB, and it is highly
recommended not to change this setting.
Caution:
Setting the volume too high will cause
distortion in voice quality and/or
missed DTMF digits.