Configure And Activate Update Failure And Attack Alerts - NETGEAR UTM9S Reference Manual

Prosecure unified threat management (utm) appliance
Hide thumbs Also See for UTM9S:
Table of Contents

Advertisement

Note:
The VPN tunnel should be established automatically, and the
syslogs should be sent to the syslog server at Site 1. You can use
the IPSec VPN Connection Status screen to verify the connection.

Configure and Activate Update Failure and Attack Alerts

You can configure the UTM to send an email alert when a failure, malware attack, malware
outbreak attack, Intrusion Prevention System (IPS) attack, or IPS outbreak attack occurs. Six
types of alerts (seven types for the UTM9S) are supported:
Update failure alert. Sent when an attempt to update any component such as a pattern
file or scan engine firmware fails.
Malware alert. Sent when the UTM detects a malware threat.
ReadyNAS failure alert (UTM9S only). Sent when an integrated ReadyNAS is down or
disconnected.
License expiration alert. Sent when one or more licenses (web protection, email
protection, support and maintenance) are near their expiration dates and when they
expire.
Malware outbreak alert. Sent when the malware outbreak criteria that you have
configured are reached or exceeded. Outbreak criteria are based on the number of
malware threats detected within a specified period of time.
IPS alert. Sent when the UTM detects an attack.
IPS outbreak alert. Sent when the IPS outbreak criteria that you have configured are
reached or exceeded. Outbreak criteria are based on the number of IPS attacks detected
within a specified period of time.
To configure and activate the email alerts:
1.
Select Monitoring > Logs & Reports > Alerts. The Alerts screen displays:
ProSecure Unified Threat Management (UTM) Appliance