Identifying Problems Using Trouble Indicators and Status LEDs
Table 6-3
Diagnostic Panel LEDs (continued)
Diagnostic Panel LED
PS2
CPU
VRM
CNFG
MEM
NMI
S ERR
SP
DASD
RAID
FAN
TEMP
BRD
PCI
Cisco Wide Area Application Engine 7341, 7371, and 674 Hardware Installation Guide
6-18
Description
The power supply in bay 2 failed.
A microprocessor failed.
An error occurred on the microprocessor voltage regulator module
(VRM).
A hardware configuration error has occurred.
A memory error has occurred.
A machine check error has occurred.
Reserved.
Service processor failure.
A hard disk drive error has occurred.
A RAID controller error has occurred.
A fan has failed, is operating too slowly, or has been removed.
The system temperature has exceeded a threshold level.
An error has occurred on the system board.
An error has occurred on a PCI bus or on the system board.