Symptoms and Solutions
Table 6-20
POST Error Codes (continued)
Error Code Symptom
151
Real-time clock error.
161
Real-time clock battery error.
162
Device configuration error.
163
Real-time clock error (time of day
not set).
175
Hardware error.
184
Power-on password damaged.
187
VPD serial number not set.
189
An attempt was made to access the
device with invalid passwords.
289
DIMM disabled by POST or user.
Cisco Wide Area Application Engine 7341, 7371, and 674 Hardware Installation Guide
6-50
Chapter 6
Troubleshooting the System Hardware
Cause and Action
Check the battery.
1.
Check the system board.
2.
Check the battery.
1.
Check the system board.
2.
Run the Configuration/Setup Utility program,
1.
choose Load Default Settings, and save the
settings.
Check the battery.
2.
Check for failing device.
3.
Check the system board.
4.
Run the Configuration/Setup Utility program,
1.
choose Load Default Settings, make sure that
the date and time are correct, and save the
settings.
Check the battery.
2.
3.
Check the system board.
Check the system board.
Restart the device and enter the administrator
1.
password; then, run the Configuration/Setup
Utility program, choose Load Default
Settings, and save the settings.
Check the battery.
2.
Check the system board.
3.
Check the system board.
Check your passwords.
Check for a disabled DIMM, if not disabled by
the user.
OL-15012-02