Novell SENTINEL RAPID DEPLOYMENT 6.1 - 12-2009 User Manual page 197

Table of Contents

Advertisement

Options
Trust Event Source Time
Set Filter
11 Click Next. The Summary window displays.
11a Click Test Connection to test the event source.
The Test Event Source window displays with Data and Error tabs. The Error tab displays
the error message if there is any error in the configuration of event source.
After a few seconds, a sampling of raw data should be received from the event source and
displayed in the tab.
11b Click the Start and Stop buttons to start or stop the test.
Use the Maximum Rows component to control the maximum number of raw data records
to obtain at once.
12 Click Finish.
NOTE: The Collector parsing script is executed on the same system as the Collector Manager that
you select here.
Description
Select Trust Event Source Time to display the Device Time (time when
the event occurred) instead of the Event Source Time (time when the
event was reported to the console).
Set the filter by using the Set Filter button. In the Filter window, add/
edit the filters and click OK.
Event Source Management 197