Reset The Plane Function - HEIDENHAIN ITNC 530 User Manual

Conversational programming
Hide thumbs Also See for ITNC 530:
Table of Contents

Advertisement

Reset the PLANE function

Show the soft-key row with special functions
Select special TNC functions: Press the
SPECIAL TNC FUNCTIONS soft key.
Select the PLANE function: Press the TILT
MACHINING PLANE soft key: The TNC displays the
available definition possibilities in the soft-key row.
Select the Reset function. This internally resets the
PLANE function, but does not change the current axis
positions.
Specify whether the TNC should automatically move
the rotary axes to the default setting (MOVE or TURN) or
not (STAY) (see "Automatic positioning: MOVE/TURN/
STAY (entry is mandatory)" on page 499).
To terminate entry, press the END key.
The PLANE RESET function resets the current PLANE
function—or an active Cycle 19—completely (angles = 0
and function is inactive). It does not need to be defined
more than once.
HEIDENHAIN iTNC 530
Example: NC block
25 PLANE RESET MOVE SET UP 50 F1000