Suppress limit switch message: M150
Standard behavior
The TNC stops program run with an error message if the tool were to
leave the active working space during a positioning block. The error
message is output before the positioning block is executed.
Behavior with M150
If the end point of a positioning block with M150 is outside the current
working space, the TNC moves the tool to the edge of the working
space, and then continues the program run without an error message.
Danger of collision!
Keep in mind that the approach path to the position
programmed after the M150 block might be changed
significantly!
M150 is also effective on traverse range limits defined
with the MOD function.
Effect
M150 is effective only in the block in which it is programmed.
M150 becomes effective at the start of block.
HEIDENHAIN iTNC 530