Position display in the tilted system
On activation of Cycle 19, the displayed positions (ACTL and NOML) and
the datum indicated in the additional status display are referenced to
the tilted coordinate system. The positions displayed immediately
after cycle definition might not be the same as the coordinates of the
last programmed position before Cycle 19.
Workspace monitoring
The TNC monitors only those axes in the tilted coordinate system that
are moved. If necessary, the TNC outputs an error message.
Positioning in a tilted coordinate system
With the miscellaneous function M130 you can move the tool, while
the coordinate system is tilted, to positions that are referenced to the
non-tilted coordinate system (see "Miscellaneous Functions for
Coordinate Data" on page 262).
Positioning movements with straight lines that are referenced to the
machine coordinate system (blocks with M91 or M92) can also be
executed in a tilted working plane. Constraints:
Positioning is without length compensation.
Positioning is without machine geometry compensation.
Tool radius compensation is not permitted.
Combining coordinate transformation cycles
When combining coordinate transformation cycles, always make sure
the working plane is swiveled around the active datum. You can
program a datum shift before activating Cycle 19. In this case, you are
shifting the machine-based coordinate system.
If you program a datum shift after having activated Cycle 19, you are
shifting the tilted coordinate system.
Important: When resetting the cycles, use the reverse sequence used
for defining them:
1. Activate the datum shift.
2. Activate tilting function
3. Activate rotation
...
Machining
...
1. Reset the rotation
2. Reset the tilting function
3. Reset the datum shift
Automatic workpiece measurement in the tilted system
The TNC measuring cycles enable you to have the TNC measure a
workpiece in a tilted system automatically. The TNC stores the
measured data in Q parameters for further processing (for example,
for printout).