FN19: PLC: Transferring values to the PLC
The function FN 19: PLC transfers up to two numerical values or
Q parameters to the PLC.
Increments and units: 0.1 µm or 0.0001°
Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC
56 FN19: PLC=+10/+Q3
HEIDENHAIN iTNC 530