HEIDENHAIN ITNC 530 User Manual page 643

Conversational programming
Hide thumbs Also See for ITNC 530:
Table of Contents

Advertisement

External data transfer
Integrating TNC interfaces EXT1 (5020.0)
and EXT2 (5020.1) to an external device
Interface type for EXT1 (5030.0) and
EXT2 (5030.1)
3-D Touch Probes
Select signal transmission
Probing feed rate for triggering touch
probes
Maximum traverse to first probe point
Safety clearance to probing point during
automatic measurement
Rapid traverse for triggering touch probes
HEIDENHAIN iTNC 530
MP5020.x
7 data bits (ASCII code, 8th bit = parity): +0
8 data bits (ASCII code, 9th bit = parity): +1
Block Check Character (BCC) any: +0
Block Check Character (BCC) control character not permitted: +2
Transmission stop through RTS active: +4
Transmission stop through RTS inactive: +0
Transmission stop through DC3 active: +8
Transmission stop through DC3 inactive: +0
Character parity even: +0
Character parity odd: +16
Character parity not desired: +0
Character parity desired: +32
Number of stop bits that are transmitted at the end of a character:
1 stop bit: +0
2 stop bits: +64
1 stop bit: +128
1 stop bit: +192
Example:
Use the following setting to adjust the TNC interface EXT2 (MP 5020.1) to
an external non-HEIDENHAIN device:
8 data bits, any BCC, transmission stop through DC3, even character
parity, character parity desired, 2 stop bits
Input for MP 5020.1: 1+0+8+0+32+64 = 105
MP5030.x
Standard transmission: 0
Interface for blockwise transfer: 1
MP6010
Touch probe with cable transmission: 0
Touch probe with infrared transmission: 1
MP6120
1 to 3000 [mm/min]
MP6130
0.001 to 99 999.9999 [mm]
MP6140
0.001 to 99 999.9999 [mm]
MP6150
1 to 300 000 [mm/min]
643

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Itnc 530 e

Table of Contents