4-4 Communication Function
Register
No.
1203h
Base frequency
1204h
Maximum frequency
1205h
O/OI selection
1206h
O2 selection
4
1207h
to
Not used
120Ah
120Bh
O start frequency
120Ch
120Dh
O end frequency
120Eh
120Fh
O start ratio
1210h
O end ratio
1211h
O start selection
1212h
O, O2, OI sampling
1213h
Not used
1214h
Not used
1215h
Multi-step speed selection
1216h
Multi-step speed
reference 0
1217h
1218h
Multi-step speed
reference 1
1219h
121Ah
Multi-step speed
reference 2
121Bh
121Ch
Multi-step speed
reference 3
121Dh
4-179
Function
Function name
code
A003
A004
A005
A006
A011
(HIGH)
A011
(LOW)
A012
(HIGH)
A012
(LOW)
A013
A014
A015
A016
A019
A020
(HIGH)
A020
(LOW)
A021
(HIGH)
A021
(LOW)
A022
(HIGH)
A022
(LOW)
A023
(HIGH)
A023
(LOW)
R/W
Monitor and setting parameters
R/W
30 to Max. frequency
R/W
30 to 400
0: Switches between O/OI
1: Switches between O/O2
R/W
2: Switches between O/VR
3: Switches between OI/VR
4: Switches between O2/VR
0: O2 only
1: O/OI auxiliary speed (not reversible)
R/W
2: O/OI auxiliary speed (reversible)
3: O2 disabled
R/W
0 to 40000
R/W
0 to 40000
R/W
O to Oend ratio
R/W
O start ratio to 100
0: External start frequency
R/W
1: 0 Hz
1 to 30
R/W
31: 500-ms filter with a hysteresis of
±0.1 Hz
0: Binary
R/W
1: Bit
R/W
0/Starting frequency to Max. frequency
R/W
R/W
0/Starting frequency to Max. frequency
R/W
R/W
0/Starting frequency to Max. frequency
R/W
R/W
0/Starting frequency to Max. frequency
R/W
Resolution
1 [Hz]
1 [Hz]
0.01 [Hz]
0.01 [Hz]
1 [%]
1 [%]
1
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]
0.01 [Hz]