Omron RX User Manual page 64

200 v class three-phase input 0.4 to 55 kw; 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for RX:
Table of Contents

Advertisement

3-6 Parameter Transition
Direct Code Specification and Selection
• The codes can be specified or selected by directly entering each digit of the codes or data, as well
as by scrolling the codes of the monitor, basic function, and extended function modes.
• Below is an example where monitor mode code "d001" is changed to extended function code
"A029".
1. Display the monitor mode code.
("d001" is displayed.)
3
*2 *3
2. Change the extended function mode.
(Continued to the next page)
3-15
dk0k0k1
Press
and
dk0k0k1
Press
(2 times).
("A001" is displayed.)
ak0k0k1
Press
.
*2
("A" is entered.)
simultaneously.
*1
• "d" of the 4th digit on the left starts to blink.
• "A" blinks.
*3
• Press the Enter key to fix the blinking digit.