Omron RX User Manual page 68

200 v class three-phase input 0.4 to 55 kw; 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for RX:
Table of Contents

Advertisement

3-7 Parameter List
Parameter
Function name
No.
d016
Total RUN time
Power ON time
d017
monitor
3
Fin temperature
d018
monitor
Motor temperature
d019
monitor
Life assessment
d022
monitor
d023
Not used
d024
Not used
d025
Not used
d026
Not used
d027
Not used
Pulse counter
d028
monitor
Position command
d029
monitor
Current position
d030
monitor
Fault frequency
d080
monitor
d081
Fault monitor 1 (Latest)
d082
Fault monitor 2
d083
Fault monitor 3
d084
Fault monitor 4
d085
Fault monitor 5
d086
Fault monitor 6
d090
Warning monitor
d102
DC voltage monitor
Regenerative
d103
braking load rate
monitor
Electronic thermal
d104
monitor
3-19
Monitor or data range
0. to 9999.
1000 to 9999 (10000 to 99990)
⎡100 to ⎡999 (100000 to 999000)
0. to 9999.
1000 to 9999 (10000 to 99990)
⎡100 to ⎡999 (100000 to 999000)
-020. to 200.0
-020. to 200.0
1: Capacitor on the main circuit board
ON
2: Cooling fan rotation speed reduced
OFF
2
1
0 to 2147483647 (Displays MSB 4 digits)
-1073741823 to 1073741823
(Displays MSB 4 digits including "-")
-1073741823 to 1073741823
(Displays MSB 4 digits including "-")
0. to 9999.
1000 to 6553 (10000 to 65530)
Error code (condition of occurrence)
→Output frequency [Hz] → Output current [A]
→Internal DC voltage [V]
→RUN time [h]
→ON time [h]
Warning code
0.0 to 999.9
0.0 to 100.0
0.0 to 100.0
Changes
Default
during
Unit
Page
setting
operation
h
h
°C
°C
4-132
Time
V
%
%
4-4
4-4
4-4
4-5
4-5
4-5
4-5
4-5
4-5
4-6
4-6
4-6
4-6
4-6
4-6
4-6
4-6
4-6
4-7