Parameter
Function name
No.
Multi-step position
P060
command 0
Multi-step position
P061
command 1
Multi-step position
P062
command 2
Multi-step position
P063
command 3
Multi-step position
P064
command 4
Multi-step position
P065
command 5
Multi-step position
P066
command 6
Multi-step position
P067
command 7
P068
Zero return mode
Zero return direction
P069
selection
Low-speed zero
P070
return frequency
High-speed zero
P071
return frequency
Position range
P072
specification
(forward)
Position range
P073
specification
(reverse)
P074
Teaching selection
P100
to
Not used
P131
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
Monitor or data range
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
Position range specification (reverse side) to
Position range specification (forward
side)(Displays MSB 4 digits including "-")
00: Low
01: Hi1
02: Hi2
00: Forward side
01: Reverse side
0.00 to 10.00
0.00 to 99.99
100.0 to Maximum frequency
0 to 268435455 (at P012 = 02)
0 to 1073741823 (at P012 = 03)
(Displays MSB 4 digits)
-268435455 to 0 (at P012 = 02)
-1073741823 to 0 (at P012 = 03)
(Displays MSB 4 digits including "-")
00: Multi-step position command 0 (P060)
01: Multi-step position command 1 (P061)
02: Multi-step position command 2 (P062)
03: Multi-step position command 3 (P063)
04: Multi-step position command 4 (P064)
05: Multi-step position command 5 (P065)
06: Multi-step position command 6 (P066)
07: Multi-step position command 7 (P067)
Do not use.
Appendix-1 Parameter List
Changes
Default
during
Unit
setting
operation
0
0
0
0
Yes
0
0
0
0
00
Yes
00
Yes
0.00
Yes
Hz
0.00
Yes
Hz
Yes
268435455
Yes
-268435455
00
Yes
0.