Omron RX User Manual page 185

200 v class three-phase input 0.4 to 55 kw; 400 v class three-phase input 0.4 to 132 kw
Hide thumbs Also See for RX:
Table of Contents

Advertisement

2nd/3rd Control Function
•You can switch between three motors to control the Inverter by allocating 08 (SET)/17 (SET3) to
any of multi-function inputs 1 to 8 (C001 to C008) and then turning on/off the SET/SET3 terminal.
Parameter No.
Function name
Multi-function input 1
C001
selection *
Multi-function input 2
C002
selection
Multi-function input 3
C003
selection *
Multi-function input 4
C004
selection
Multi-function input 5
C005
selection
Multi-function input 6
C006
selection
Multi-function input 7
C007
selection
Multi-function input 8
C008
selection
*1. When the emergency shutoff function is enabled (SW1 = ON), C001 and C003 are forced to change to "18"
(RS) and "64" (EMR), respectively. (You cannot intentionally set "64".)
If SW1 is turned on and then off, C003 is set to "no" (no allocation).
01: RV (reverse)
02: CF1 (multi-step speed setting binary 1)
03: CF2 (multi-step speed setting binary 2)
04: CF3 (multi-step speed setting binary 3)
1
05: CF4 (multi-step speed setting binary 4)
06: JG (jogging)
07: DB (external DC injection braking)
08: SET (2nd control)
09: 2CH (2-step acceleration/deceleration)
11: FRS (free-run stop)
12: EXT (external trip)
13: USP (USP function)
14: CS (commercial switching)
15: SFT (soft lock)
16: AT (analog input switching)
17: SET3 (3rd control)
18: RS (reset)
20: STA (3-wire start)
21: STP (3-wire stop)
22: F/R (3-wire forward/reverse)
23: PID (PID enabled/disabled)
24: PIDC (PID integral reset)
1
26: CAS (control gain switching)
27: UP (UP/DWN function accelerated)
28: DWN (UP/DWN function decelerated)
29: UDC (UP/DWN function data clear)
31: OPE (forced operator)
32: SF1 (multi-step speed setting bit 1)
33: SF2 (multi-step speed setting bit 2)
34: SF3 (multi-step speed setting bit 3)
35: SF4 (multi-step speed setting bit 4)
36: SF5 (multi-step speed setting bit 5)
37: SF6 (multi-step speed setting bit 6)
38: SF7 (multi-step speed setting bit 7)
39: OLR (overload limit switching)
40: TL (torque limit enabled)
41: TRQ1 (torque limit switching 1)
42: TRQ2 (torque limit switching 2)
43: PPI (P/PI switching)
44: BOK (brake confirmation)
45: ORT (orientation)
46: LAC (LAD cancel)
47: PCLR (position deviation clear)
48: STAT (pulse train position command input permission)
50: ADD (frequency addition)
51: F-TM (forced terminal)
52: ATR (torque command input permission)
53: KHC (integrated power clear)
54: SON (servo ON)
55: FOC (preliminary excitation)
56: Not used
57: Not used
58: Not used
59: Not used
60: Not used
61: Not used
62: Not used
63: Not used
65: AHD (analog command held)
66: CP1 (position command selection 1)
67: CP2 (position command selection 2)
68: CP3 (position command selection 3)
69: ORL (zero return limit signal)
70: ORG (zero return startup signal)
71: FOT (forward driving stop)
72: ROT (reverse driving stop)
73: SPD (speed/position switching)
74: PCNT (pulse counter)
75: PCC (pulse counter clear)
no: NO (no allocation)
4-2 Function Mode
Data
Default setting
Unit
01
18
12
02
03
04
05
06
4-80
4