Appendix-1 Parameter List
Parameter
Function name
No.
P036
Torque bias mode
P037
Torque bias value
Torque bias polarity
P038
selection
Speed limit value in
P039
torque control
(forward)
Speed limit value in
P040
torque control
(reverse)
P044
Not used
Operation setting at
P045
communications error
Output assembly
P046
instance No. setting
Input assembly
P047
instance No. setting
Operation setting at
P048
idle mode detection
Polarity setting for
P049
rotation speed
Pulse train frequency
P055
scale
Pulse train frequency
P056
filter time constant
Pulse train frequency
P057
bias amount
Pulse train frequency
P058
limit
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.
App-35
Monitor or data range
00: None
01: Digital Operator
02: Terminal O2
-200. to +200. (0.4 to 55 kW)
-180. to +180. (75 to 132 kW)
00: Signed
01: Depends on the RUN direction
0.00 to Maximum frequency
0.00 to Maximum frequency
Use "1.00".
*Do not change.
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free run
04: Deceleration stop
20
21
100
70
71
101
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free run
04: Deceleration stop
0/2/4/6/8/10/12/14/16/18/20/22/24/26/28/30/
32/34/36/38
1.0 to 50.0
0.01 to 2.00
-100. to +100.
0. to 100.
Changes
Default
during
Unit
Page
setting
operation
00
No
4-122
0.
Yes
%
4-123
00
No
0.00
Yes
Hz
4-122
0.00
Yes
Hz
1.00
No
s
01
No
21
No
71
No
01
No
0
No
25.0
No
kHz
0.10
No
s
4-138
0.
No
%
100.
No
%